Data & Methodology — Walker County

Full contaminant data, sample history, and sourcing for Walker County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

142 well testing events on record, covering 20 analytes. Data spans 1962 to 2017.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Radon 1 2012 100%
360% of limit ↑ 900% above
PFOS municipal 13 2023–2025 46%
186% of limit ↑ 43% above
Manganese 81 1968–2021 93%
98% of limit ↑ 52% above
Iron 117 1959–2021 85%
37% of limit ↓ 76% below
PFOA municipal 13 2023–2025 15%
126% of limit ~ typical
Arsenic 70 1992–2021 27%
61% of limit ↑ 60% above
Chloride 3 1977–2012 100%
27% of limit ↓ 25% below
Fluoride 110 1961–2021 92%
5% of limit ↓ 78% below
HFPO-DA (GenX) municipal 13 2023–2025 0%
— —
Lead 68 1992–2021 13%
19% of limit ~ typical
Nitrate 7 1992–2012 14%
0% of limit ↓ 98% below
Nitrite 1 2012 0%
— —
PFHxS municipal 13 2023–2025 46%
76% of limit ↑ 71% above
PFNA municipal 13 2023–2025 0%
— —
Sulfate 3 1977–2012 100%
5% of limit ↓ 81% below
Uranium 24 2005–2021 4%
0% of limit ↓ 100% below
Sodium 2 2011–2012 100%
— ↓ 30% below
pH 4 1977–2012 100%
— ~ typical
PFBS municipal 13 2023–2025 54%
— ↑ 36% above
Hardness 3 1977–2012 100%
— ↓ 60% below

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Walker County

Of the 70 arsenic tests on record for Walker County (1992–2021), 73% found none.

Of the 110 fluoride tests on record for Walker County (1961–2021), 8% found none, and half were below 200 µg/L.

Of the 117 iron tests on record for Walker County (1959–2021), 15% found none, and half were below 100 µg/L.

Of the 68 lead tests on record for Walker County (1992–2021), 87% found none.

Of the 81 manganese tests on record for Walker County (1968–2021), 7% found none, and half were below 43.7 µg/L.

Of the 24 uranium tests on record for Walker County (2005–2021), 96% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Manganese 81 samples
  • Iron 117 samples
  • Arsenic 70 samples
  • Fluoride 110 samples
  • Lead 68 samples
  • Uranium 24 samples

Limited data (<15 samples) — interpret with caution

  • Radon 1 sample
  • Chloride 3 samples
  • Nitrate 7 samples
  • Nitrite 1 sample
  • Sulfate 3 samples
  • Sodium 2 samples
  • pH 4 samples
  • Hardness 3 samples

No private-well PFAS data for Walker County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Walker County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Walker County

32 Active public water systems
71,007 Residents on public water
14% Households on private wells

Public water systems in Walker County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Walker County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Walker County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.6% 6.1% 2020
Arsenic Kidney disease rate 3.2% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Walker County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04