Data & Methodology — McLennan County

Full contaminant data, sample history, and sourcing for McLennan County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

754 well testing events on record, covering 22 analytes. Data spans 1961 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Radon 2 2016 100%
108% of limit ↑ 201% above
Iron 529 1940–2020 75%
30% of limit ↓ 81% below
Arsenic 162 1979–2020 28%
90% of limit ↑ 135% above
Nitrate 40 1970–2016 42%
0% of limit ↓ 99% below
Fluoride 680 1940–2020 100%
35% of limit ↑ 46% above
Manganese 387 1941–2020 35%
4% of limit ↓ 94% below
Chloride 2 2016 100%
19% of limit ↓ 48% below
HFPO-DA (GenX) municipal 108 2023–2025 0%
— —
Lead 156 1978–2020 18%
10% of limit ↓ 38% below
Nitrite 2 2016 0%
— —
PFHxS municipal 108 2023–2025 3%
32% of limit ↓ 27% below
PFNA municipal 108 2023–2025 0%
— —
PFOA municipal 108 2023–2025 0%
— —
PFOS municipal 108 2023–2025 0%
— —
Sulfate 2 2016 100%
69% of limit ↑ 143% above
Uranium 42 2011–2020 12%
4% of limit ↓ 76% below
Total Coliform 2 2016 0%
— —
Sodium 2 2016 100%
— ↑ 146% above
pH 2 2016 100%
— ~ typical
PFBS municipal 108 2023–2025 2%
— ↓ 22% below
Hardness 2 2016 100%
— ↓ 92% below
E. coli 2 2016 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with McLennan County

Of the 162 arsenic tests on record for McLennan County (1979–2020), 72% found none.

Of the 680 fluoride tests on record for McLennan County (1940–2020), 0% found none, and half were below 1.4 mg/L.

Of the 529 iron tests on record for McLennan County (1940–2020), 25% found none, and half were below 52 µg/L.

Of the 156 lead tests on record for McLennan County (1978–2020), 82% found none.

Of the 387 manganese tests on record for McLennan County (1941–2020), 65% found none.

Of the 40 nitrate tests on record for McLennan County (1970–2016), 57% found none.

Of the 42 uranium tests on record for McLennan County (2011–2020), 88% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 529 samples
  • Arsenic 162 samples
  • Nitrate 40 samples
  • Fluoride 680 samples
  • Manganese 387 samples
  • Lead 156 samples
  • Uranium 42 samples

Limited data (<15 samples) — interpret with caution

  • Radon 2 samples
  • Chloride 2 samples
  • Nitrite 2 samples
  • Sulfate 2 samples
  • Total Coliform 2 samples
  • Sodium 2 samples
  • pH 2 samples
  • Hardness 2 samples
  • E. coli 2 samples

No private-well PFAS data for McLennan County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in McLennan County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in McLennan County

58 Active public water systems
285,868 Residents on public water
3% Households on private wells

Public water systems in McLennan County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in McLennan County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition McLennan County Prevalence TX Average Source Year
Arsenic Cancer prevalence 6.0% 6.1% 2020
Arsenic Kidney disease rate 3.3% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download McLennan County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →