Data & Methodology — Karnes County

Full contaminant data, sample history, and sourcing for Karnes County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

237 well testing events on record, covering 20 analytes. Data spans 1961 to 2017.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Chloride 14 1990–2016 86%
139% of limit ↑ 290% above
Arsenic 59 1988–2020 64%
234% of limit ↑ 513% above
Manganese 77 1955–2020 42%
13% of limit ↓ 80% below
Iron 114 1945–2020 58%
33% of limit ↓ 78% below
Nitrate 19 1990–2016 84%
17% of limit ↓ 23% below
Fluoride 228 1945–2020 99%
18% of limit ↓ 27% below
HFPO-DA (GenX) municipal 7 2024 0%
— —
Lead 59 1988–2020 25%
7% of limit ↓ 61% below
Nitrite 8 2006–2016 0%
— —
PFHxS municipal 7 2024 0%
— —
PFNA municipal 7 2024 0%
— —
PFOA municipal 7 2024 0%
— —
PFOS municipal 7 2024 0%
— —
Radon 1 2013 100%
52% of limit ↑ 45% above
Sulfate 14 1990–2016 100%
14% of limit ↓ 50% below
Uranium 22 1990–2020 77%
31% of limit ↑ 99% above
Sodium 14 1990–2016 100%
— ↑ 134% above
pH 14 1990–2016 100%
— ~ typical
PFBS municipal 7 2024 0%
— —
Hardness 14 1990–2016 100%
— ↑ 94% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Karnes County

Of the 59 arsenic tests on record for Karnes County (1988–2020), 36% found none, and half were below 6.3 µg/L.

Of the 228 fluoride tests on record for Karnes County (1945–2020), 1% found none, and half were below 700 µg/L.

Of the 114 iron tests on record for Karnes County (1945–2020), 42% found none, and half were below 22 µg/L.

Of the 59 lead tests on record for Karnes County (1988–2020), 75% found none.

Of the 77 manganese tests on record for Karnes County (1955–2020), 58% found none.

Of the 22 uranium tests on record for Karnes County (1990–2020), 23% found none, and half were below 7.98 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Arsenic 59 samples
  • Manganese 77 samples
  • Iron 114 samples
  • Nitrate 19 samples
  • Fluoride 228 samples
  • Lead 59 samples
  • Uranium 22 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 14 samples
  • Nitrite 8 samples
  • Radon 1 sample
  • Sulfate 14 samples
  • Sodium 14 samples
  • pH 14 samples
  • Hardness 14 samples

No private-well PFAS data for Karnes County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Karnes County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Karnes County

9 Active public water systems
19,487 Residents on public water
3% Households on private wells

Public water systems in Karnes County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Karnes County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Karnes County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.3% 6.1% 2020
Arsenic Kidney disease rate 3.3% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Karnes County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →