Data & Methodology — Jim Hogg County

Full contaminant data, sample history, and sourcing for Jim Hogg County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

82 well testing events on record, covering 20 analytes. Data spans 2013 to 2013.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Chloride 1 2013 100%
108% of limit ↑ 201% above
Radon 1 2013 100%
913% of limit ↑ 2437% above
Sulfate 1 2013 100%
108% of limit ↑ 279% above
Arsenic 42 1990–2021 76%
147% of limit ↑ 285% above
Nitrate 12 1990–2013 92%
37% of limit ↑ 66% above
Lead 42 1990–2021 7%
11% of limit ↓ 33% below
Iron 45 1968–2021 58%
24% of limit ↓ 84% below
Fluoride 75 1968–2021 97%
20% of limit ~ typical
HFPO-DA (GenX) municipal 6 2024 0%
— —
Manganese 44 1968–2021 59%
5% of limit ↓ 92% below
Nitrite 1 2013 0%
— —
PFHxS municipal 6 2024 0%
— —
PFNA municipal 6 2024 0%
— —
PFOA municipal 6 2024 0%
— —
PFOS municipal 6 2024 0%
— —
Uranium 9 1990–2021 100%
13% of limit ~ typical
Sodium 1 2013 100%
— ↑ 299% above
pH 1 2013 100%
— ~ typical
PFBS municipal 6 2024 0%
— —
Hardness 1 2013 100%
— ↓ 94% below

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Jim Hogg County

Of the 42 arsenic tests on record for Jim Hogg County (1990–2021), 24% found none, and half were below 7.7 µg/L.

Of the 75 fluoride tests on record for Jim Hogg County (1968–2021), 3% found none, and half were below 800 µg/L.

Of the 45 iron tests on record for Jim Hogg County (1968–2021), 42% found none, and half were below 29 µg/L.

Of the 42 lead tests on record for Jim Hogg County (1990–2021), 93% found none.

Of the 44 manganese tests on record for Jim Hogg County (1968–2021), 41% found none, and half were below 1.23 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Arsenic 42 samples
  • Lead 42 samples
  • Iron 45 samples
  • Fluoride 75 samples
  • Manganese 44 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 1 sample
  • Radon 1 sample
  • Sulfate 1 sample
  • Nitrate 12 samples
  • Nitrite 1 sample
  • Uranium 9 samples
  • Sodium 1 sample
  • pH 1 sample
  • Hardness 1 sample

No private-well PFAS data for Jim Hogg County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Jim Hogg County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Jim Hogg County

1 Active public water systems
5,397 Residents on public water
10% Households on private wells

Public water systems in Jim Hogg County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Jim Hogg County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Jim Hogg County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.3% 6.1% 2020
Arsenic Kidney disease rate 4.5% 3.3% 2020
Lead Heart disease rate 7.3% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Jim Hogg County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →