Data & Methodology — Hockley County

Full contaminant data, sample history, and sourcing for Hockley County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

343 well testing events on record, covering 22 analytes. Data spans 2003 to 2016.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Radon 1 2016 100%
287% of limit
Fluoride 335 1947–2021 100%
102% of limit
Arsenic 124 1988–2021 87%
74% of limit
Manganese 125 1971–2021 53%
30% of limit
Sulfate 5 2003–2016 100%
60% of limit
Chloride 5 2003–2016 100%
56% of limit
Nitrate 20 1990–2016 100%
33% of limit
PFOS municipal 8 2023–2024 12%
105% of limit
Uranium 28 2003–2021 100%
51% of limit
Iron 129 1971–2021 32%
9% of limit
HFPO-DA (GenX) municipal 8 2023–2024 0%
Lead 123 1988–2021 20%
10% of limit
Nitrite 6 2003–2016 33%
0% of limit
PFHxS municipal 8 2023–2024 0%
PFNA municipal 8 2023–2024 0%
PFOA municipal 8 2023–2024 0%
E. coli 1 2016 0%
Hardness 5 2003–2016 100%
PFBS municipal 8 2023–2024 0%
pH 6 2003–2016 100%
Sodium 5 2003–2016 100%
Total Coliform 1 2016 0%

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Fluoride 335 samples
  • Arsenic 124 samples
  • Manganese 125 samples
  • Nitrate 20 samples
  • Uranium 28 samples
  • Iron 129 samples
  • Lead 123 samples

Limited data (<15 samples) — interpret with caution

  • Radon 1 sample
  • Sulfate 5 samples
  • Chloride 5 samples
  • Nitrite 6 samples
  • E. coli 1 sample
  • Hardness 5 samples
  • pH 6 samples
  • Sodium 5 samples
  • Total Coliform 1 sample

No private-well PFAS data for Hockley County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Hockley County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Hockley County

9 Active public water systems
16,308 Residents on public water

Public water systems in Hockley County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Hockley County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Hockley County Prevalence TX Average Source Year
Arsenic Kidney disease rate 3.2% 3.3% 2020
Arsenic Cancer prevalence 5.4% 6.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Hockley County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →