Data & Methodology — Gaines County

Full contaminant data, sample history, and sourcing for Gaines County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

1108 well testing events on record, covering 22 analytes. Data spans 2001 to 2016.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Arsenic 217 1963–2021 96%
144% of limit ↑ 277% above
Fluoride 1104 1938–2021 100%
102% of limit ↑ 329% above
Sulfate 19 2001–2016 100%
94% of limit ↑ 228% above
Chloride 19 2001–2016 100%
87% of limit ↑ 144% above
Nitrate 62 1989–2016 98%
37% of limit ↑ 68% above
Iron 268 1945–2021 53%
18% of limit ↓ 88% below
Uranium 75 2001–2021 100%
23% of limit ↑ 50% above
Manganese 253 1956–2021 34%
4% of limit ↓ 94% below
HFPO-DA (GenX) municipal 6 2024 0%
— —
Lead 215 1989–2021 11%
6% of limit ↓ 64% below
Nitrite 20 2001–2016 25%
1% of limit ↓ 32% below
PFHxS municipal 6 2024 0%
— —
PFNA municipal 6 2024 0%
— —
PFOA municipal 6 2024 0%
— —
PFOS municipal 6 2024 0%
— —
Radon 5 2001–2016 100%
9% of limit ↓ 76% below
E. coli 1 2016 0%
— —
Hardness 19 2001–2016 100%
— ↑ 132% above
PFBS municipal 6 2024 0%
— —
pH 20 2001–2016 100%
— ~ typical
Sodium 19 2001–2016 100%
— ↓ 24% below
Total Coliform 1 2016 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Gaines County

Of the 217 arsenic tests on record for Gaines County (1963–2021), 4% found none, and half were below 14.3 µg/L.

Of the 1104 fluoride tests on record for Gaines County (1938–2021), 0% found none, and half were below 4.1 mg/L.

Of the 268 iron tests on record for Gaines County (1945–2021), 47% found none, and half were below 90 ng/L.

Of the 215 lead tests on record for Gaines County (1989–2021), 89% found none.

Of the 253 manganese tests on record for Gaines County (1956–2021), 66% found none.

Of the 62 nitrate tests on record for Gaines County (1989–2016), 2% found none, and half were below 3.73 mg/L.

Of the 75 uranium tests on record for Gaines County (2001–2021), 0% found none, and half were below 6.97 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Arsenic 217 samples
  • Fluoride 1104 samples
  • Sulfate 19 samples
  • Chloride 19 samples
  • Nitrate 62 samples
  • Iron 268 samples
  • Uranium 75 samples
  • Manganese 253 samples
  • Lead 215 samples
  • Nitrite 20 samples
  • Hardness 19 samples
  • pH 20 samples
  • Sodium 19 samples

Limited data (<15 samples) — interpret with caution

  • Radon 5 samples
  • E. coli 1 sample
  • Total Coliform 1 sample

No private-well PFAS data for Gaines County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Gaines County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Gaines County

9 Active public water systems
10,373 Residents on public water
37% Households on private wells

Public water systems in Gaines County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Gaines County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Gaines County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.3% 6.1% 2020
Arsenic Kidney disease rate 3.1% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Gaines County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →