Full contaminant data, sample history, and sourcing for Fort Bend County. For readers who want to go beyond the summary.
Contaminant Data — All Analytes
891 well testing events on record, covering
20 analytes.
Data spans 1936 to 2025.
Contaminant
Samples
Years
Detection Rate
Distribution LowModHigh
vs. Limit
vs. TX Avg
Radon
9
2002–2015
100%
363% of limit
↑ 909% above
Iron
280
1933–2021
82%
47% of limit
↓ 70% below
Manganese
208
1958–2021
75%
51% of limit
↓ 21% below
Chloride
356
1936–2018
99%
24% of limit
↓ 33% below
PFOS
municipal
299
2023–2025
2%
105% of limit
~ typical
Nitrate
89
1967–2014
73%
0% of limit
↓ 99% below
Arsenic
164
1988–2021
46%
31% of limit
~ typical
PFOA
municipal
299
2023–2025
1%
101% of limit
~ typical
Fluoride
447
1939–2021
100%
8% of limit
↓ 69% below
HFPO-DA (GenX)
municipal
299
2023–2025
0%
—
—
Lead
149
1988–2021
5%
12% of limit
↓ 29% below
Nitrite
4
2002–2014
0%
—
—
PFHxS
municipal
299
2023–2025
4%
33% of limit
↓ 25% below
PFNA
municipal
299
2023–2025
0%
—
—
Sulfate
109
1936–2015
98%
5% of limit
↓ 82% below
Uranium
51
2002–2021
63%
6% of limit
↓ 65% below
Hardness
96
1936–2015
100%
—
~ typical
PFBS
municipal
299
2023–2025
9%
—
~ typical
pH
333
1963–2018
100%
—
~ typical
Sodium
95
1936–2015
100%
—
↓ 39% below
Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.
Compare your result with Fort Bend County
Of the 164 arsenic tests on record for Fort Bend County (1988–2021),
54% found none.
Of the 356 chloride tests on record for Fort Bend County (1936–2018),
1% found none, and half were below 59.6 mg/L.
Of the 447 fluoride tests on record for Fort Bend County (1939–2021),
0% found none, and half were below 300 µg/L.
Of the 280 iron tests on record for Fort Bend County (1933–2021),
18% found none, and half were below 100 µg/L.
Of the 149 lead tests on record for Fort Bend County (1988–2021),
95% found none.
Of the 208 manganese tests on record for Fort Bend County (1958–2021),
25% found none, and half were below 20 µg/L.
Of the 89 nitrate tests on record for Fort Bend County (1967–2014),
27% found none.
Of the 109 sulfate tests on record for Fort Bend County (1936–2015),
2% found none, and half were below 12.3 mg/L.
Of the 51 uranium tests on record for Fort Bend County (2002–2021),
37% found none, and half were below 0.737 µg/L.
Data Coverage & Gaps
Well-sampled analytes (15+ samples)
Iron 280 samples
Manganese 208 samples
Chloride 356 samples
Nitrate 89 samples
Arsenic 164 samples
Fluoride 447 samples
Lead 149 samples
Sulfate 109 samples
Uranium 51 samples
Hardness 96 samples
pH 333 samples
Sodium 95 samples
Limited data (<15 samples) — interpret with caution
Radon 9 samples
Nitrite 4 samples
No private-well PFAS data for Fort Bend County
We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Fort Bend County.
PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination.
PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →
Public vs. Private Water in Fort Bend County
293Active public water systems
891,650Residents on public water
10%Households on private wells
Public water systems in Fort Bend County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.
CDC Health Outcome Correlations
Where contaminants detected in Fort Bend County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.
This report aggregates data from the following public databases:
Water Quality Portal (WQP) — groundwater sample results for Fort Bend County from EPA, USGS, and state agencies. Browse WQP data →
EPA Safe Drinking Water Information System (SDWIS) — public water system inventory used to estimate the share of residents on private wells. Browse SDWIS →
Census ACS 5-Year Estimates — well and cistern household counts (variable DP04_0074E) used to calculate the private-well percentage for Fort Bend County. Census data explorer →
USGS Aquifer Atlas — principal aquifer type underlying Fort Bend County, which informs which contaminants are geologically likely. USGS Aquifer Atlas →
EPA UCMR 5 (2023–2025) — PFAS occurrence data from public water systems, used as a proxy indicator for aquifer PFAS exposure. Rows marked "municipal" in the table above come from this source. About UCMR 5 →
EPA Toxics Release Inventory (TRI) — industrial facility chemical releases near Fort Bend County, used in contamination risk scoring. TRI Explorer →
EPA Superfund NPL — National Priorities List sites in or near Fort Bend County, used in contamination risk scoring. Superfund site search →
CDC PLACES — county-level health outcome prevalence (kidney disease, cancer, heart disease) correlated with detected contaminants. About CDC PLACES →
Methodology
Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.
Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.
State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.