Data & Methodology — Erath County

Full contaminant data, sample history, and sourcing for Erath County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

413 well testing events on record, covering 22 analytes. Data spans 1962 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 221 1939–2019 55%
62% of limit ↓ 60% below
PFOS municipal 14 2023–2025 14%
215% of limit ↑ 65% above
Nitrate 118 1990–2016 87%
8% of limit ↓ 66% below
Manganese 210 1939–2019 39%
22% of limit ↓ 66% below
Arsenic 227 1988–2019 1%
10% of limit ↓ 74% below
Chloride 1 2016 100%
9% of limit ↓ 74% below
Fluoride 396 1939–2019 99%
9% of limit ↓ 63% below
HFPO-DA (GenX) municipal 14 2023–2025 0%
— —
Lead 181 1988–2019 13%
13% of limit ↓ 23% below
Nitrite 1 2016 0%
— —
PFHxS municipal 14 2023–2025 0%
— —
PFNA municipal 14 2023–2025 0%
— —
PFOA municipal 14 2023–2025 0%
— —
Radon 1 2016 100%
38% of limit ~ typical
Sulfate 1 2016 100%
8% of limit ↓ 71% below
Uranium 35 2011–2019 91%
10% of limit ↓ 32% below
E. coli 1 2016 0%
— —
Hardness 1 2016 100%
— ↑ 27% above
PFBS municipal 14 2023–2025 0%
— —
pH 1 2016 100%
— ~ typical
Sodium 1 2016 100%
— ↓ 78% below
Total Coliform 1 2016 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Erath County

Of the 227 arsenic tests on record for Erath County (1988–2019), 99% found none.

Of the 396 fluoride tests on record for Erath County (1939–2019), 1% found none, and half were below 350 µg/L.

Of the 221 iron tests on record for Erath County (1939–2019), 45% found none, and half were below 20 µg/L.

Of the 181 lead tests on record for Erath County (1988–2019), 87% found none.

Of the 210 manganese tests on record for Erath County (1939–2019), 61% found none.

Of the 118 nitrate tests on record for Erath County (1990–2016), 13% found none, and half were below 665 µg/L.

Of the 35 uranium tests on record for Erath County (2011–2019), 9% found none, and half were below 2.98 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 221 samples
  • Nitrate 118 samples
  • Manganese 210 samples
  • Arsenic 227 samples
  • Fluoride 396 samples
  • Lead 181 samples
  • Uranium 35 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 1 sample
  • Nitrite 1 sample
  • Radon 1 sample
  • Sulfate 1 sample
  • E. coli 1 sample
  • Hardness 1 sample
  • pH 1 sample
  • Sodium 1 sample
  • Total Coliform 1 sample

No private-well PFAS data for Erath County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Erath County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Erath County

31 Active public water systems
34,413 Residents on public water
32% Households on private wells

Public water systems in Erath County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Erath County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Erath County Prevalence TX Average Source Year
Nitrate Cancer prevalence 5.9% 6.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Erath County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →