Data & Methodology — Cameron County

Full contaminant data, sample history, and sourcing for Cameron County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

415 well testing events on record, covering 20 analytes. Data spans 1966 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Radon 1 2013 100%
133% of limit ↑ 270% above
Manganese 58 1973–2021 93%
262% of limit ↑ 307% above
Arsenic 57 1988–2021 68%
142% of limit ↑ 272% above
Iron 125 1945–2021 87%
153% of limit ~ typical
PFOS municipal 63 2023–2025 25%
120% of limit ~ typical
PFOA municipal 63 2023–2025 5%
118% of limit ~ typical
Lead 52 1988–2021 8%
27% of limit ↑ 60% above
Fluoride 361 1944–2021 100%
28% of limit ~ typical
Chloride 1 2013 100%
33% of limit ~ typical
HFPO-DA (GenX) municipal 63 2023–2025 0%
— —
Nitrate 6 1994–2013 83%
0% of limit ↓ 100% below
Nitrite 1 2013 0%
— —
PFHxS municipal 63 2023–2025 29%
36% of limit ~ typical
PFNA municipal 63 2023–2025 0%
— —
Sulfate 1 2013 100%
43% of limit ↑ 51% above
Uranium 11 2005–2021 82%
20% of limit ↑ 31% above
PFBS municipal 63 2023–2025 10%
— ↓ 21% below
Hardness 1 2013 100%
— ↑ 47% above
Sodium 1 2013 100%
— ~ typical
pH 1 2013 100%
— ~ typical

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Cameron County

Of the 57 arsenic tests on record for Cameron County (1988–2021), 32% found none, and half were below 10.5 µg/L.

Of the 361 fluoride tests on record for Cameron County (1944–2021), 0% found none, and half were below 1.1 mg/L.

Of the 125 iron tests on record for Cameron County (1945–2021), 13% found none, and half were below 380 µg/L.

Of the 52 lead tests on record for Cameron County (1988–2021), 92% found none.

Of the 58 manganese tests on record for Cameron County (1973–2021), 7% found none, and half were below 122 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Manganese 58 samples
  • Arsenic 57 samples
  • Iron 125 samples
  • Lead 52 samples
  • Fluoride 361 samples

Limited data (<15 samples) — interpret with caution

  • Radon 1 sample
  • Chloride 1 sample
  • Nitrate 6 samples
  • Nitrite 1 sample
  • Sulfate 1 sample
  • Uranium 11 samples
  • Hardness 1 sample
  • Sodium 1 sample
  • pH 1 sample

No private-well PFAS data for Cameron County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Cameron County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

CDC Health Outcome Correlations

Where contaminants detected in Cameron County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Cameron County Prevalence TX Average Source Year
Arsenic Cancer prevalence 4.5% 6.1% 2020
Arsenic Kidney disease rate 3.8% 3.3% 2020
Lead Heart disease rate 7.6% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Cameron County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →