Data & Methodology — Angelina County

Full contaminant data, sample history, and sourcing for Angelina County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

482 well testing events on record, covering 20 analytes. Data spans 1959 to 2015.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Sulfate 2 2015 100%
78% of limit ↑ 174% above
Iron 373 1937–2018 82%
50% of limit ↓ 68% below
Manganese 243 1939–2018 41%
40% of limit ↓ 38% below
Lead 113 1977–2018 12%
10% of limit ↓ 43% below
Fluoride 406 1937–2018 99%
10% of limit ↓ 58% below
Arsenic 113 1977–2018 7%
20% of limit ↓ 48% below
Chloride 2 2015 100%
21% of limit ↓ 41% below
HFPO-DA (GenX) municipal 29 2023–2025 0%
— —
Nitrate 15 1983–2015 27%
1% of limit ↓ 97% below
Nitrite 2 2015 50%
1% of limit ↓ 32% below
PFHxS municipal 29 2023–2025 0%
— —
PFNA municipal 29 2023–2025 0%
— —
PFOA municipal 29 2023–2025 0%
— —
PFOS municipal 29 2023–2025 0%
— —
Radon 1 2015 100%
16% of limit ↓ 55% below
Uranium 24 2009–2018 8%
1% of limit ↓ 93% below
pH 2 2015 100%
— ~ typical
PFBS municipal 29 2023–2025 0%
— —
Hardness 2 2015 100%
— ↓ 93% below
Sodium 2 2015 100%
— ↑ 82% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Angelina County

Of the 113 arsenic tests on record for Angelina County (1977–2018), 93% found none.

Of the 406 fluoride tests on record for Angelina County (1937–2018), 1% found none, and half were below 400 µg/L.

Of the 373 iron tests on record for Angelina County (1937–2018), 18% found none, and half were below 100 µg/L.

Of the 113 lead tests on record for Angelina County (1977–2018), 88% found none.

Of the 243 manganese tests on record for Angelina County (1939–2018), 59% found none.

Of the 24 uranium tests on record for Angelina County (2009–2018), 92% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 373 samples
  • Manganese 243 samples
  • Lead 113 samples
  • Fluoride 406 samples
  • Arsenic 113 samples
  • Nitrate 15 samples
  • Uranium 24 samples

Limited data (<15 samples) — interpret with caution

  • Sulfate 2 samples
  • Chloride 2 samples
  • Nitrite 2 samples
  • Radon 1 sample
  • pH 2 samples
  • Hardness 2 samples
  • Sodium 2 samples

No private-well PFAS data for Angelina County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Angelina County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Angelina County

26 Active public water systems
103,137 Residents on public water
0% Households on private wells

Public water systems in Angelina County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Angelina County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Angelina County Prevalence TX Average Source Year
Lead Heart disease rate 8.5% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Angelina County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →