Data & Methodology — Juniata County

Full contaminant data, sample history, and sourcing for Juniata County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

70 well testing events on record, covering 22 analytes. Data spans 1934 to 2023.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. PA Avg
Radon 9 1993–2023 100%
120% of limit ~ typical
Manganese 14 1966–2023 100%
50% of limit ↓ 90% below
Iron 20 1934–2023 95%
13% of limit ↓ 98% below
PFOS municipal 54 2025 22%
66% of limit ↓ 48% below
Arsenic 11 1980–2023 36%
7% of limit ↓ 76% below
Chloride 21 1934–2023 95%
2% of limit ↓ 85% below
Fluoride 17 1966–2023 82%
2% of limit ↓ 44% below
HFPO-DA (GenX) municipal 48 2025 0%
— —
Lead 6 1980–2023 33%
10% of limit ↑ 105% above
Nitrate 31 1934–2023 97%
20% of limit ~ typical
Nitrite 23 1980–2023 17%
0% of limit ↓ 77% below
PFHxS municipal 4 2025 0%
— —
PFNA municipal 4 2025 0%
— —
PFOA municipal 54 2025 11%
49% of limit ↓ 47% below
Sulfate 21 1934–2023 95%
7% of limit ↓ 58% below
Uranium 5 1993–2023 40%
2% of limit ~ typical
Total Coliform 2 1993–2023 60%
— ~ typical
Sodium 18 1934–2023 83%
— ↓ 86% below
pH 31 1966–2023 100%
— ~ typical
PFBS municipal 48 2025 8%
— ↓ 44% below
Hardness 21 1934–2023 100%
— ~ typical
E. coli 2 1998–2023 25%
— ~ typical

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across PA.

Compare your result with Juniata County

Of the 21 chloride tests on record for Juniata County (1934–2023), 5% found none, and half were below 3 mg/L.

Of the 20 iron tests on record for Juniata County (1934–2023), 5% found none, and half were below 38 µg/L.

Of the 31 nitrate tests on record for Juniata County (1934–2023), 3% found none, and half were below 1.65 mg/L.

Of the 50 pfoa tests on record for Juniata County (2025), 88% found none.

Of the 50 pfos tests on record for Juniata County (2025), 76% found none.

Of the 21 sulfate tests on record for Juniata County (1934–2023), 5% found none, and half were below 16 mg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 20 samples
  • PFOS 54 samples
  • Chloride 21 samples
  • Fluoride 17 samples
  • HFPO-DA (GenX) 48 samples
  • Nitrate 31 samples
  • Nitrite 23 samples
  • PFOA 54 samples
  • Sulfate 21 samples
  • Sodium 18 samples
  • pH 31 samples
  • PFBS 48 samples
  • Hardness 21 samples

Limited data (<15 samples) — interpret with caution

  • Radon 9 samples
  • Manganese 14 samples
  • Arsenic 11 samples
  • Lead 6 samples
  • Uranium 5 samples
  • Total Coliform 2 samples
  • E. coli 2 samples

Public vs. Private Water in Juniata County

37 Active public water systems
13,839 Residents on public water
72% Households on private wells

Public water systems in Juniata County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Juniata County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Juniata County Prevalence PA Average Source Year
PFOS Cancer prevalence 8.1% 7.0% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Juniata County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in PA with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →