Data & Methodology — Hudson County

Full contaminant data, sample history, and sourcing for Hudson County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

42 well testing events on record, covering 19 analytes. Data spans 1968 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. NJ Avg
PFOA municipal 30 2022–2025 90%
185% of limit ↑ 196% above
Manganese 17 1969–2022 82%
8300% of limit ↑ 4050% above
PFOS municipal 29 2022–2025 52%
155% of limit ↑ 675% above
Iron 17 1969–2022 88%
39% of limit ↓ 89% below
Chloride 17 1969–2022 100%
68% of limit ~ typical
Sulfate 17 1969–2022 100%
37% of limit ↑ 122% above
Arsenic 13 1987–2022 92%
5% of limit ↓ 87% below
Fluoride 17 1969–2022 88%
5% of limit ↓ 24% below
HFPO-DA (GenX) municipal 30 2022–2025 0%
Lead 13 1986–2022 23%
1% of limit ↓ 98% below
Nitrate 16 1969–2022 62%
15% of limit
Nitrite 13 1987–2022 38%
0% of limit ↓ 94% below
PFHxS municipal 28 2022–2025 39%
43% of limit ↑ 2050% above
PFNA municipal 30 2022–2025 3%
25% of limit
Uranium 1 1986 100%
29% of limit ↑ 630% above
Sodium 17 1969–2022 100%
↓ 44% below
pH 19 1969–2022 100%
~ typical
PFBS municipal 30 2022–2025 10%
↑ 1233% above
Hardness 17 1969–2022 100%
↑ 278% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across NJ.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • PFOA 30 samples
  • Manganese 17 samples
  • PFOS 29 samples
  • Iron 17 samples
  • Chloride 17 samples
  • Sulfate 17 samples
  • Fluoride 17 samples
  • HFPO-DA (GenX) 30 samples
  • Nitrate 16 samples
  • PFHxS 28 samples
  • PFNA 30 samples
  • Sodium 17 samples
  • pH 19 samples
  • PFBS 30 samples
  • Hardness 17 samples

Limited data (<15 samples) — interpret with caution

  • Arsenic 13 samples
  • Lead 13 samples
  • Nitrite 13 samples
  • Uranium 1 sample

Public vs. Private Water in Hudson County

6 Active public water systems
435,495 Residents on public water

Public water systems in Hudson County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Hudson County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Hudson County Prevalence NJ Average Source Year
PFOA Cancer prevalence 4.8% 6.2% 2020
Arsenic Kidney disease rate 2.5% 2.7% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Hudson County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in NJ with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →