Data & Methodology — Walker County

Full contaminant data, sample history, and sourcing for Walker County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

30 well testing events on record, covering 19 analytes. Data spans 1960 to 2022.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. GA Avg
PFOA municipal 28 2024–2025 54%
158% of limit ~ typical
Iron 13 1970–2022 62%
367% of limit ↑ 792% above
PFOS municipal 28 2024–2025 36%
288% of limit ↑ 103% above
Manganese 13 1970–2022 69%
20% of limit ↓ 67% below
Lead 9 1970–2022 44%
0% of limit ↓ 77% below
Nitrate 13 1960–2022 100%
5% of limit ~ typical
PFHxS municipal 28 2023–2025 7%
48% of limit ~ typical
Sulfate 17 1960–2022 100%
1% of limit ↓ 40% below
PFNA municipal 28 2023–2025 0%
Arsenic 9 1970–2022 11%
0% of limit ↓ 100% below
Chloride 17 1960–2022 100%
1% of limit ↓ 54% below
Uranium 4 2013–2022 100%
1% of limit ↑ 42% above
Lead 9 1970–2022 44%
0% of limit ↓ 77% below
E. coli 2 2013–2022 50%
~ typical
PFBS municipal 28 2024–2025 93%
↑ 416% above
pH 17 1960–2022 100%
~ typical
Hardness 17 1960–2022 100%
~ typical
Sodium 17 1960–2022 100%
↓ 64% below
Total Coliform 2 2013–2022 100%
~ typical

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across GA.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Sulfate 17 samples
  • Chloride 17 samples
  • pH 17 samples
  • Hardness 17 samples
  • Sodium 17 samples

Limited data (<15 samples) — interpret with caution

  • Iron 13 samples
  • Manganese 13 samples
  • Lead 9 samples
  • Nitrate 13 samples
  • Arsenic 9 samples
  • Uranium 4 samples
  • Lead 9 samples
  • E. coli 2 samples
  • Total Coliform 2 samples

No private-well PFAS data for Walker County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Walker County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Walker County

6 Active public water systems
64,179 Residents on public water

Public water systems in Walker County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Walker County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Walker County Prevalence GA Average Source Year
PFOA Cancer prevalence 6.0% 6.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Walker County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in GA with at least one sample for that analyte.

Last updated: 2026-08-03

Full methodology →