Data & Methodology — Columbia County

Full contaminant data, sample history, and sourcing for Columbia County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

38 well testing events on record, covering 14 analytes. Data spans 1958 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. GA Avg
Iron 30 2002–2006 40%
9% of limit ↓ 79% below
Sulfate 34 1958–2006 91%
2% of limit ~ typical
PFOS municipal 8 2024–2025 0%
PFHxS municipal 8 2024–2025 0%
Nitrate 34 1958–2006 85%
2% of limit ↓ 69% below
Sulfate 34 1958–2006 91%
2% of limit ~ typical
PFOS municipal 8 2024–2025 0%
Nitrate 34 1958–2006 85%
2% of limit ↓ 69% below
PFHxS municipal 8 2024–2025 0%
PFOA municipal 8 2024–2025 0%
Hardness 34 1958–2006 97%
↓ 27% below
PFBS municipal 8 2024–2025 0%
pH 34 1958–2006 100%
~ typical
Sodium 34 1958–2006 97%
↑ 120% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across GA.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 30 samples
  • Sulfate 34 samples
  • Nitrate 34 samples
  • Sulfate 34 samples
  • Nitrate 34 samples
  • Hardness 34 samples
  • pH 34 samples
  • Sodium 34 samples

No private-well PFAS data for Columbia County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Columbia County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Columbia County

11 Active public water systems
145,192 Residents on public water

Public water systems in Columbia County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in GA with at least one sample for that analyte.

Last updated: 2026-08-03

Full methodology →