Data & Methodology — Brantley County

Full contaminant data, sample history, and sourcing for Brantley County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

16 well testing events on record, covering 13 analytes. Data spans 1937 to 2023.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. GA Avg
Iron 6 1971–2013 83%
65% of limit ↑ 57% above
Lead 3 1971–2013 33%
0% of limit ↓ 100% below
Manganese 4 1971–2013 75%
7% of limit ↓ 89% below
Nitrate 8 1940–2013 75%
0% of limit ↓ 98% below
Sulfate 10 1940–2013 100%
19% of limit ↑ 835% above
Radon 1 2005 100%
5% of limit ↓ 73% below
Uranium 2 2005–2013 0%
Arsenic 3 1971–2013 67%
0% of limit ↓ 96% below
Uranium 2 2005–2013 0%
Sulfate 10 1940–2013 100%
19% of limit ↑ 835% above
Hardness 11 1940–2013 100%
↑ 141% above
pH 11 1959–2013 100%
~ typical
Sodium 10 1940–2013 100%
↑ 153% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across GA.

Data Coverage & Gaps

Limited data (<15 samples) — interpret with caution

  • Iron 6 samples
  • Lead 3 samples
  • Manganese 4 samples
  • Nitrate 8 samples
  • Sulfate 10 samples
  • Radon 1 sample
  • Uranium 2 samples
  • Arsenic 3 samples
  • Uranium 2 samples
  • Sulfate 10 samples
  • Hardness 11 samples
  • pH 11 samples
  • Sodium 10 samples

No private-well PFAS data for Brantley County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Brantley County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Brantley County

15 Active public water systems
5,677 Residents on public water

Public water systems in Brantley County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in GA with at least one sample for that analyte.

Last updated: 2026-08-03