Full contaminant data, sample history, and sourcing for Leon County. For readers who want to go beyond the summary.
Contaminant Data — All Analytes
1397 well testing events on record, covering
23 analytes.
Data spans 1957 to 2024.
Contaminant
Samples
Years
Detection Rate
Distribution LowModHigh
vs. Limit
vs. FL Avg
Iron
317
1973–2025
74%
14% of limit
↓ 93% below
Manganese
336
1972–2025
51%
40% of limit
↑ 51% above
Nitrate
963
1972–2015
95%
8% of limit
↑ 159% above
PFOS
municipal
70
2023–2025
7%
198% of limit
~ typical
Arsenic
343
1972–2025
44%
10% of limit
↓ 23% below
Sulfate
594
1972–2025
97%
2% of limit
↓ 93% below
Nitrite
976
1972–2015
55%
1% of limit
~ typical
Chloride
1213
1972–2025
100%
2% of limit
↓ 95% below
PFNA
municipal
70
2023–2025
0%
—
—
PFOA
municipal
70
2023–2025
0%
—
—
Fluoride
585
1972–2025
81%
2% of limit
↓ 65% below
HFPO-DA (GenX)
municipal
70
2023–2025
0%
—
—
PFHxS
municipal
70
2023–2025
4%
35% of limit
↓ 32% below
Lead
337
1972–2025
23%
1% of limit
↓ 58% below
Radon
2
1993–2015
100%
34% of limit
~ typical
Uranium
5
1993–2015
80%
2% of limit
↑ 86% above
Hardness
552
1973–2015
97%
—
↓ 53% below
Total Coliform
67
1980–2025
34%
—
~ typical
Sodium
789
1973–2025
100%
—
↓ 95% below
E. coli
37
2015–2025
97%
—
~ typical
Fecal Coliform
30
1980–2021
16%
—
~ typical
PFBS
municipal
70
2023–2025
1%
—
↓ 34% below
pH
1124
1971–2025
100%
—
~ typical
Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across FL.
Compare your result with Leon County
Of the 343 arsenic tests on record for Leon County (1972–2025),
56% found none.
Of the 1213 chloride tests on record for Leon County (1972–2025),
0% found none, and half were below 5.6 mg/L.
Of the 585 fluoride tests on record for Leon County (1972–2025),
19% found none, and half were below 100 µg/L.
Of the 317 iron tests on record for Leon County (1973–2025),
26% found none, and half were below 30 µg/L.
Of the 337 lead tests on record for Leon County (1972–2025),
77% found none.
Of the 336 manganese tests on record for Leon County (1972–2025),
49% found none, and half were below 0.75 µg/L.
Of the 963 nitrate tests on record for Leon County (1972–2015),
5% found none, and half were below 690 µg/L.
Of the 594 sulfate tests on record for Leon County (1972–2025),
3% found none, and half were below 4.7 mg/L.
Data Coverage & Gaps
Well-sampled analytes (15+ samples)
Iron 317 samples
Manganese 336 samples
Nitrate 963 samples
Arsenic 343 samples
Sulfate 594 samples
Nitrite 976 samples
Chloride 1213 samples
Fluoride 585 samples
Lead 337 samples
Hardness 552 samples
Total Coliform 67 samples
Sodium 789 samples
E. coli 37 samples
Fecal Coliform 30 samples
pH 1124 samples
Limited data (<15 samples) — interpret with caution
Radon 2 samples
Uranium 5 samples
No private-well PFAS data for Leon County
We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Leon County.
PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination.
PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →
Public vs. Private Water in Leon County
41Active public water systems
236,457Residents on public water
16%Households on private wells
Public water systems in Leon County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.
CDC Health Outcome Correlations
Where contaminants detected in Leon County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.
This report aggregates data from the following public databases:
Water Quality Portal (WQP) — groundwater sample results for Leon County from EPA, USGS, and state agencies. Browse WQP data →
EPA Safe Drinking Water Information System (SDWIS) — public water system inventory used to estimate the share of residents on private wells. Browse SDWIS →
Census ACS 5-Year Estimates — well and cistern household counts (variable DP04_0074E) used to calculate the private-well percentage for Leon County. Census data explorer →
USGS Aquifer Atlas — principal aquifer type underlying Leon County, which informs which contaminants are geologically likely. USGS Aquifer Atlas →
EPA UCMR 5 (2023–2025) — PFAS occurrence data from public water systems, used as a proxy indicator for aquifer PFAS exposure. Rows marked "municipal" in the table above come from this source. About UCMR 5 →
EPA Toxics Release Inventory (TRI) — industrial facility chemical releases near Leon County, used in contamination risk scoring. TRI Explorer →
EPA Superfund NPL — National Priorities List sites in or near Leon County, used in contamination risk scoring. Superfund site search →
CDC PLACES — county-level health outcome prevalence (kidney disease, cancer, heart disease) correlated with detected contaminants. About CDC PLACES →
Methodology
Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.
Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.
State comparison uses the median of county median values across all counties in FL with at least one sample for that analyte.